Product Name: Flux Gate Leakage Current Sensor
Product Series: FC * * -63S**
Input current: 6mADC/30mAC B-type leakage current sensor
0.01A~0.5ADC or other
Power supply voltage: Dual power supply ± 12~± 15V
Single power supply 12V, 5V
Linearity: 1.0%
Output: Analog or switch quantity
This is new type of Fluxgate Current Sensor; it’s based on the principle of magnetic modulation.
it can be used to measure leakage currents including DC, AC, and AC and DC stacks, generally used
as a DC leakage current detection and protection in equipment that uses DC operation
Used in electric vehicle charging pile (mode3 protection)
Primary and secondary isolation, pressure and safety.
Applied to a single power supply system,output switching signal, achieve better protection, power supply and action current support customized.
More Choices
Feature:
Various type for choose and OEM
Beautiful and small weight.
Easy to install.
Flame retardant (UL94- V0).
Environmental protection( EU RoHS)
Advantage:
High precision
Low loss during insertion.
Strong overload capabiliy
Fast reaction
Strong anti-interference ability
Describe
Use :
Communication base station equipment
New energy equipment
DC charging pile
Communication power
Switching power
Medical equipment
Rail transit
Industrial measurement
Power control
Size
Circuit schematic
Note: This schematic diagram is the basic working principle of the transformer. We can design the transformer sampling circuit for the customer.
Operation diagram:
Instructions for use:
1. Connect the current according to the calibration direction of the circuit diagram, pay attention to the direction of current.
2. Connect the wire according to the function pin definition of the calibration in the structure diagram.
Specification
Parameter |
FCVS-63S91 |
FCVS-63S92 |
FCVS-63S93 |
FCVS-63S94 |
Unit |
|
Ipn |
Input Current |
6mA DC |
6mA DC/ 10mA AC |
6mA DC/ 30mA AC |
6mA DC/ 20mA AC |
mA |
Vsn |
Output |
0-3/0-4/0-5 |
VDC |
|||
Rm |
Load Resistance |
≥10kΩ |
kΩ |
|||
Vc |
Power Voltage |
±12 |
V DC |
|||
Ic |
Current Drain |
≤18 |
mA |
|||
Vd |
Insulation withstand voltage |
3 (50Hz/min) |
kV |
|||
Vo |
Zero offset voltage |
≤50 |
mV |
|||
VoT |
Offset voltage warm drift |
≤±1 |
mV/℃ |
|||
Tr |
Reaction Time |
≤20 |
µS |
|||
Ta |
Working Temperature |
-20~+80 |
℃ |
|||
Ts |
Storage Temperature |
-40~+85 |
℃ |
Note: If there is no product suitable for your use in the above table, we can tailor the product according to your technical and structural requirements.