Product Name: Hall Current Sensor
Product Series: HOVS-64S** Series Hall Current Sensor(single power)
Input current: 50ADC/300AC hall current sensor
400A~600ADC or other
Power supply voltage: Single power supply ± 12~± 15V (±5%)
Single power supply 12V, 5V
Linearity: ≤0.5 ( T=25℃)
Output: Analog or switch quantity
This series of products is a new type of switchable Hall current sensor that can be used for measuring DC, AC, high-frequency, pulse, and various irregular waveform current signals.
The primary and secondary sides are completely isolated to ensure electrical withstand voltage safety.
Applied to 5V or 12V single power supply system.
More Choices
Feature:
Beautiful and small weight . Easy to install.
Flame retardan (UL94- V0). Environmental protection(EU RoHS))
Advantage:
High precision, Low loss during insertion.
Fast reaction, Strong overload capability
Good linearity, Strong anti-interference ability
low null offset, low temperature drift
Frequency bandwidth
Describe
Application:
Communication base station equipment
New energy equipment, Welding machine power supply
communication power supply
switching power supply
instrumentation and meters
medical equipment
rail transit
Industrial measurement
power control
Size
Circuit schematic
Note: This schematic diagram is the basic working principle of the transformer. We can design the transformer sampling circuit for the customer.
Specification
|
Project |
Performance |
|||||
|
Model |
HOVS-64S*1 |
HOVS-64S*2 |
HOVS-64S*3 |
HOVS-64S*4 |
Unit |
|
|
Rated input current |
50A |
100A |
200A |
300A |
A |
|
|
Measuring current range |
±50 |
±100 |
±200 |
±300 |
A |
|
|
Rated output voltage |
2.5±2 (T=25℃) |
V |
|
|||
|
Load Resistance |
≥10 |
kΩ |
||||
|
Power Voltage |
+5V (* represents 1), +12V (* represents 2) |
VDC |
||||
|
Current consumption |
≤15 |
mA |
||||
|
Null offset voltage |
<±20 ( T=25℃) |
mV |
||||
|
Magnetic misalignment voltage |
<±10 ( T=25℃) |
mV |
||||
|
Offset voltage temperature drift |
≤±0.5mV/℃(IP=0 T=-40~+105℃) |
mV/℃ |
||||
|
linearity |
≤0.5 ( T=25℃) |
% |
||||
|
Overall accuracy |
≤1 .0 ( T=25℃ VC=±15V) |
% |
||||
|
Reaction timer |
<5 |
µS |
||||
|
insulation withstand voltage |
4.0 |
kV/Min |
||||
|
-3db bandwidth |
DC…30 |
kHz |
||||
|
Working temperature |
-40~+105 |
℃ |
||||
|
Storage temperature |
-40~+105 |
℃
|
||||
|
Project |
Performance |
|||||
|
Model |
HOVS-64S*5 |
HOVS-64S*6 |
HOVS-64S*7 |
Unit |
||
|
Rated input current |
400A |
500A |
600A |
A |
||
|
Measuring current range |
±400 |
±500 |
±800 |
A |
||
|
Rated output voltage |
2.5±2 (T=25℃) |
V |
|
|||
|
Load Resistance |
≥10 |
kΩ |
||||
|
Power Voltage |
+5V (* represents 1), +12V (* represents 2) |
VDC |
||||
|
Current consumption |
≤15 |
mA |
||||
|
Null offset voltage |
<±20 ( T=25℃) |
mV |
||||
|
Magnetic misalignment voltage |
<±10 ( T=25℃) |
mV |
||||
|
Offset voltage temperature drift |
≤±0.5mV/℃(IP=0 T=-40~+105℃) |
mV/℃ |
||||
|
linearity |
≤0.5 ( T=25℃) |
% |
||||
|
Overall accuracy |
≤1 .0 ( T=25℃ VC=±15V) |
% |
||||
|
Reaction timer |
<5 |
µS |
||||
|
insulation withstand voltage |
4.0 |
kV/Min |
||||
|
-3db bandwidth |
DC…30 |
kHz |
||||
|
Working temperature |
-40~+105 |
℃ |
||||
|
Storage temperature |
-40~+105 |
℃
|
||||
Note: If there is no product suitable for your use in the above table, we can tailor the product according to your technical and structural requirements.