Product Name: Flux Gate Leakage Current Sensor
Product Series: FC * * -63S**
Input current: 6mADC/30mAC B-type leakage current sensor
0.01A~0.5ADC or other
Power supply voltage: Dual power supply ± 12~± 15V
Single power supply 12V, 5V
Linearity: 1.0%
Output: Analog or switch quantity
This is new type of Fluxgate Current Sensor; it’s based on the principle of magnetic modulation. It can be used for measurement of DC leakage current,provides security for DC operating systems Primary and secondary isolation, pressure and safety.Used in dual power supply systems, the power supply and output voltage can be customized according to customer needs.
More Choices
Feature:
Various type for choose and OEM
Beautiful and small weight . Easy to install.
Flame retardan (UL94- V0). Environmental protection(EU RoHS))
Advantage:
High precision, Low loss during insertion.
Fast reaction, Strong overload capability
Good linearity, Strong anti-interference ability
low null offset, low temperature drift
Describe
Use:
Communication base station equipment
New energy equipment, DC charging pile
Communication power, Switching power
Welding machine power supply, Instrumentation
Medical equipment, Rail transit
Industrial measurement, Power control
Size
Circuit schematic
Note: This schematic diagram is the basic working principle of the transformer. We can design the transformer sampling circuit for the customer.
Operation diagram:
Instructions for use:
1. Connect the current according to the calibration direction of the circuit diagram, pay attention to the direction of current.
2. Connect the wire according to the function pin definition of the calibration in the structure diagram.
Specification
Technical Parameter:
Parameter |
FCVD-63S01 |
FCVD-63S02 |
FCVD-63S03 |
FCVD-63S04 |
FCVD-63S05 |
FCVD-63S06 |
Unit |
|
Ipn |
Rated input current |
10 |
20 |
30 |
50 |
100 |
500 |
mA |
Ip |
Measuring current range |
20 |
40 |
60 |
100 |
200 |
1000 |
mA |
Vsn |
Rated output voltage |
5 |
VDC |
|||||
Rm |
Load Resistance |
≥10kΩ |
kΩ |
|||||
Vc |
Power Voltage |
±12~±15 |
V |
|||||
Ic |
Current consumption |
≤18 |
mA |
|||||
Vd |
Insulation withstand voltage |
3 (50Hz/min) |
kV |
|||||
Vo |
Null offset voltage |
≤50 |
mV |
|||||
VoT |
Offset voltage temperature drift |
≤±1 |
mV/℃ |
|||||
εl |
linearity |
±0.5 ( T=25℃) |
% |
|||||
X |
Precision |
±1.0 |
% |
|||||
Tr |
Reaction timer |
≤20 |
µS |
|||||
Ta |
Working temperature |
-20~+80 |
℃ |
|||||
Ts |
Storage temperature |
-40~+85 |
℃ |
Note: If there is no product suitable for your use in the above table, we can tailor the product according to your technical and structural requirements.